feat(logging-p0): replace console.* with logger and add error logging before ERP throws
Eliminate console.* remnants in bootstrap, session-manager, migrations, and app entry so startup and login failures are captured in log files. Add log.error before all 14 throw sites in ERP services (auth, extractor, cleaner, browser manager) to ensure critical automation failures are traceable. Introduce capturePageContext utility for defensive Playwright page state capture during error logging. Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -3,6 +3,9 @@ import fs from 'fs'
|
||||
import { join } from 'path'
|
||||
import { ConfigManager } from '../services/config/config-manager'
|
||||
import { UpdateService } from '../services/update/update-service'
|
||||
import { createLogger } from '../services/logger'
|
||||
|
||||
const log = createLogger('Bootstrap')
|
||||
|
||||
export function configurePlaywrightBrowsersPath(): string {
|
||||
const browsersPath = join(app.getPath('userData'), 'ms-playwright')
|
||||
@@ -39,7 +42,7 @@ export function ensurePlaywrightRuntime(browsersPath: string): boolean {
|
||||
try {
|
||||
fs.mkdirSync(browsersPath, { recursive: true })
|
||||
} catch (error) {
|
||||
console.error('Failed to create browsers directory:', error)
|
||||
log.error('Failed to create browsers directory', { error })
|
||||
}
|
||||
|
||||
const newChromiumPath = join(browsersPath, 'chromium-1208', 'chrome-win64', 'chrome.exe')
|
||||
@@ -57,7 +60,7 @@ export function ensurePlaywrightRuntime(browsersPath: string): boolean {
|
||||
if (entry.startsWith('chromium-') && !entry.includes('headless')) {
|
||||
const revisionPath = join(browsersPath, entry, 'chrome-win64', 'chrome.exe')
|
||||
if (fs.existsSync(revisionPath)) {
|
||||
console.log('Found Chromium revision:', entry)
|
||||
log.info('Found Chromium revision', { revision: entry })
|
||||
foundRevision = true
|
||||
break
|
||||
}
|
||||
@@ -71,10 +74,10 @@ export function ensurePlaywrightRuntime(browsersPath: string): boolean {
|
||||
return true
|
||||
}
|
||||
|
||||
console.warn(
|
||||
'Playwright browser not found. Available:',
|
||||
fs.existsSync(browsersPath) ? fs.readdirSync(browsersPath) : 'none'
|
||||
)
|
||||
log.warn('Playwright browser not found', {
|
||||
available: fs.existsSync(browsersPath) ? fs.readdirSync(browsersPath) : 'none',
|
||||
browsersPath
|
||||
})
|
||||
return false
|
||||
}
|
||||
|
||||
@@ -84,7 +87,7 @@ export async function initializeMainProcessServices(): Promise<void> {
|
||||
await configManager.initialize()
|
||||
UpdateService.getInstance().initialize()
|
||||
} catch (error) {
|
||||
console.error('Failed to initialize ConfigManager:', error)
|
||||
log.error('Failed to initialize ConfigManager', { error })
|
||||
}
|
||||
|
||||
const { registerIpcHandlers } = await import('../ipc')
|
||||
|
||||
Reference in New Issue